337.1 / 777.4 nm photometer

Physicist verification companion · source release r4 · mathematical checks and unresolved limits

Review index · Exact coverage JSON

Remaining gaps by original question

Each row describes what still needs an empirical input, a convergence study or a matched validation. A missing physical input is not a zero, and a passing calculation does not close these gaps.

initial · Transmission to nadir at 550 km versus overhead cloud optical depth; cloud-top/above-top source; Rayleigh versus particles.

Review notebooks: 01, 02

Sources: CT003, CT029, CT041, CT045, CT048, R4-CLOUDSCAT

1 · Which radiative-transfer calculation/tool should be used, and alternatives to CloudScat?

Review notebooks: 02

Sources: CT004, CT020, CT021, CT022, CT034, CT053, R4-CLOUDSCAT

2 · Multiple scattering and temporal profile; robustness of 30-80 us versus>200 us rise-time discrimination.

Review notebooks: 02, 03, 04

Sources: CT044, DO-ELEC-MMIA-ARCH, DO-ELEC-SAMPLING-MT002, DO-RAD-ANISIMOVA2017, airfly-quenching-physics, bai2023-bath-waveform, li2021-shallow-fast, li2022-multipulse

4 · Absolute nightside 337 nm radiance: quiet airglow, moon, zodiacal light and integrated starlight.

Review notebooks: 01

Sources: BG017, BG027, BG028, BG035, BG048, BG049, BG059

5 · Auroral 337 nm 4 nm-band brightness and shot-noise floor during moderate/disturbed conditions.

Review notebooks: 01, 03

Sources: BG006, BG019, BG021, BG023, BG062, BG063, BG064

6 · Lunar phase/elevation at which cloud background dominates detector noise.

Review notebooks: 01

Sources: BG012, BG013, BG015, BG016, BG025, BG038, BG039, BG040

7 · Detector choice at 337 nm, large area and 10-50 kHz; claimed photodiode/TIA floor.

Review notebooks: 01, 03

Sources: DO-DET-GSENSE400, DO-DET-S13360-AREA, DO-DET-S8664-LARGE, DO-DET-SISMUV2025, DO-ELEC-ADI2015, DO-ELEC-TIA-BAILEY2026, DO-WIDEGAP-SG01D

8 · NEP and aperture photons per event for candidate detectors.

Review notebooks: 01, 03

Sources: DO-DET-S13360-AREA, DO-ELEC-ADC-ENBW2019, DO-ELEC-APD-NOISE, DO-ELEC-FEMTO-DLPCA, DO-METHOD-NEP2025, EU-lcsur

9 · DC coupling and preservation of a>3 ms pulse.

Review notebooks: 01

Sources: DO-ELEC-CALIOP-TRANSIENT2026, DO-ELEC-ET-DC, DO-ELEC-MMIA-ARCH, DO-RAD-ANISIMOVA2017, EU-etbase

10 · 2-3 year 550 km polar/SAA radiation effects on dark current and gain.

Review notebooks:

Sources: DO-PARTICLE-ICECUBE2011, DO-PARTICLE-TUS2021, DO-RAD-ANISIMOVA2017, DO-RAD-DSOUZA2021, DO-RAD-GRB2025, DO-RAD-GRID2022, DO-RAD-SPOOQY2025, DO-RAD-ULTRASATTID2023

11 · European suppliers for flight or near-flight detectors.

Review notebooks:

Sources: EU-et9111, EU-et9113, EU-etbase, EU-etprecautions, EU-excelfactory, EU-fsapd, EU-fsesa, EU-lcfactory, EU-lcsur, EU-photekds, EU-uvit

12 · Maximise nonimaging photometer etendue within roughly 1U.

Review notebooks: 01

Sources: DO-DET-GLIMS2011, DO-ELEC-MMIA-ARCH, DO-OPT-ETENDUE1985

13 · Maintain narrowband filter response over 60-90 degree full field.

Review notebooks: 01

Sources: DO-ELEC-MMIA-ARCH, DO-OPT-ALLUXA-THERMAL2014, DO-OPT-LIS2000

14 · Is 4 nm FWHM optimal for the N2(0, 0)band and background?

Review notebooks: 01

Sources: BG035, BG048, BG054, BG055, BG056, BG057, DO-OPT-ALLUXA337

15 · Required optical density and rejection wavelength range.

Review notebooks: 01

Sources: BG035, BG038, DO-OPT-ALLUXA337, DO-OPT-SOPAPILLA2026, DO-PARTICLE-TUS2021, juice2026-majis-spectra

16 · 777.4 nm null-channel detector and comparable photon thresholds.

Review notebooks: 01, 03

Sources: DO-DATA-LEAL2026, DO-DET-H16722-RED, DO-DET-S8664-LARGE, DO-ELEC-MMIA-ARCH, DO-PARTICLE-TUS2021, DO-RAD-ANISIMOVA2017, chuang2022-catalogue-actual-joint-flags

17 · Cross-calibration of different detector technologies for a trustworthy ratio.

Review notebooks: 01, 03

Sources: DO-CAL-CALSPEC2026, DO-CAL-NPL-ANALOG2026, DO-ELEC-MMIA-ARCH, DO-ELEC-SOPAPILLA2026, DO-OPT-NIST-WAVELENGTH

18 · On-orbit gain drift, absolute radiometric stability and peak brightness versus current.

Review notebooks:

Sources: DO-CAL-CALSPEC2026, DO-CAL-ISUAL2012, DO-CAL-JENKINS2026, DO-CAL-OMI2022, DO-CAL-OMPS2023, DO-CAL-SALDANHA2017, airfly-quenching-physics, guo2025-independent-streamer-field, pervez2024-current-inverse

19 · Ground calibration/characterisation and facilities.

Review notebooks:

Sources: DO-CAL-ESA-OOEL, DO-CAL-NIST2007, DO-CAL-NPL-ANALOG2026, DO-CAL-PTB340-2024, DO-CAL-SALDANHA2017, DO-OPT-NIST-WAVELENGTH

20 · Laboratory 337 nm source with 30 us rise and>3 ms duration.

Review notebooks: 01, 02

Sources: DO-CAL-AUGER2009, DO-CAL-ICECUBE337-2010, DO-CAL-LEDD1B, DO-CAL-M340L5

21 · Can 2-4 kg/5-10 W deliver a useful event rate at 550 km?

Review notebooks: 03, 04

Sources: DO-ELEC-MMIA-ARCH, ahmad2014-2015-uppsala-opposing-evidence, bai2023-bath-waveform, bath2023-context-waveform, bitzer2026-group-matching, night-selection-layer-shadow, soler2022-peak-bins

22 · What assumptions or physics are missing?

Review notebooks: 00, 01, 02, 03, 04

Sources: DO-CAL-SALDANHA2017, DO-ELEC-MMIA-ARCH, DO-PARTICLE-ICECUBE2011, DO-PARTICLE-TUS2021, R4-CLOUDSCAT, bai2023-bath-waveform, chuang2022-catalogue-actual-joint-flags, pervez2024-current-inverse